Return to HomepageContact LasermetAbout Lasermet

The following brochures are available to download (requires Adobe Reader)

Interlocks - ICS-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Laser Safety Products > Interlock Systems > ICS-5 Laser Interlock System

ICS-5 Laser Interlock System

ICS-1The Laser Interlock System ICS-5 is the latest development of the market-leading ICS-1 Laser Interlock Control System. It is based on the same tried-and-tested safety control system, but has been totally updated and simplified internally to include the latest in electronic technology and design. Supplied in a smaller, attractive enclosure, it has a simple, easy-to-use control panel which can be wired directly to 4 interlocks or groups of interlocks.

The ICS-5 has all the safety features of the ICS-1 and complies with the relevant European Standards – in particular EN954-1 (Category 3 Safety System); EN61508 (SIL4); EN61010 and EN 60947-1. It also conforms to the Machinery Directive; Low Voltage Directive and EMC Directive.

The ICS-5 has the same basic functions of the ICS-1, namely:


  • Interlocked mains supply
  • Interlocked low voltage supply for beam shutters
  • Laser interlock connector operators
  • Key-switch operation to prevent unauthorised use
  • Reset switch
  • Time limited fail-safe override option
  • Automatic switching of illuminated signs
  • Emergency stop circuit
  • Facility to use with mechanical or coded magnetic door switches
  • Automatic fault detection and shutdown
  • LED indication for interlock switch status; reset ready; system checked; override on

In addition it has the following extra functions:

  • Can be connected directly to up to 4 hard-wired magnetic or mechanical interlock switches or up to 4 groups of interlock switches
  • Simple, non-programmable system which is easy to set up, use and maintain in the field
  • Can be used as a local laser controller as part of a larger system, which may be controlled by a master ICS-1. Optional safety status and ready status outputs can be provided to communicate with the ICS-1 or remote indicator panel
  • Simple initial configuration with all connections being hard-wired. Not being processor-based, a PC is not needed to set up the system and an Ethernet controller is not required on every switch.
  • Surface-mounted or flush-mounted standard options. Deep option for safety contactors for switching high power or multiple lasers.
  • Dual-redundant fail-safe circuitry
  • External facility to allow the system to be disabled by an external source e.g. supervisor’s keyswitch

ICS-5 Interlock Specifications

 

ICS-5
Interlocked operator outputs 3 x output each rated at 6A at 250Vac / 50 VDC resistive load
Internal Terminals 12VDC; 24VDC and mains voltage
Warning light output 230V,1A
Connections Hard wired
Supply: 230 V, 13A
Size 265 w x 230 h x 86 deep (mm)
Weight  
Directives Conforms to Machinery Directive, Low Voltage Directive, EMC Directive