Businesses and other organisations are increasingly recognising the benefits of creating a safety culture in terms of better staff morale, reduced sickness and increased productivity. The proper interlocking of laser facilities is widely regarded as best safety practice and is thus essential for any company using lasers which has a commitment to the safety of its employees. In addition, the use of interlocks is a requirement of EN/IEC 60825-1 for all Class 4 and most Class 3B lasers whatever the application, and is usually enforced by HSE and local authority inspectors.
Choose the ICS-1 interlock and warning sign system
The ICS-1 is a comprehensive and highly flexible system for the control of laser interlocks which has been designed to meet all the relevant European Standards (in particular EN 954-1 'Safety related control systems ...' as well as EN 60825-1) and incorporates a unique safety checking circuit which ensures that the system is fail safe. It can be used with lasers of all powers and types, and incorporates automatic switching of illuminated warning signs, over-ride facility for entry or exit, operation of laser power supply, external shutters or interlock connectors and much more.
The IPS-11 is a heavy duty interlocked power supply designed as an add-on option to the ICS-1 for the interlocking of ring mains, large power supplies or multiple lasers in the same room. Please click here for more information on the IPS-11. Please call our sales department for help in designing your system.
| Functions and Features | Options |
|
|
| ICS-1 Specifications | IPS-11 Specifications | |
| Interlocked outputs | 1. 230V. 10 A 2. 12 or 24 VDC selectable, 2 A or 1 set n/o clean contacts |
1. Two 230 V. 32 A or one 415 V, 32 A 2. 12 VDC, 5 A 3. 24 VDC 1 A 4. 8 sets n/o clean contacts |
| Warning light output | 230 V, 1 A max | 230 V, 10 A |
| Supply | 230 V, 13 A | From ICS-1 plus supply for 1. above |
| Size | 300 x 400 x 100 mm | 300 x 400 x 100 mm |
| Weight | 6.2 Kg | 7.5 Kg |
| Conforms to: | Machinery Directive; Low Voltage Directive; EMC Directive |
Machinery Directive; Low Voltage Directive; EMC Directive |
| Meets: | EN 954-1, Category 3 safety system; EN 61010; EN 60947-1 |
EN 954-1, Category 3 safety system; EN 61010; EN 60947-1 |
Non-locking interlock system is the usual configuration
Locking interlock system is recommended for laser operating theatres, areas running long experiments and any situation where accidental interruption of the laser is undesirable