See also:
Laser Blocking Curtains & Screens
Laser Interlocks
We supply and install Class 1 room size laser enclosures for high power lasers. All enclosures are sold tested and certified to EN 60825-4 (Safety of Laser Products Part 4 - Laser Guards). These can be supplied complete with interlock system and illuminated signs. Fume extraction and/or air conditioning can also be supplied, as can CCTV. This is a cost effective and extremely easy method of enclosing your laser system which fulfils your safety requirements and frees up space for other activities.
The specification of the enclosure to EN 60825-4 is as follows:
Irradiated Area |
PEL (T2) 100 s | PEL (T3) 10 s |
4 mm2 |
61 MW/m2 | 34 MW/m2 |
2000 mm2 |
2.7 MW/m2 | 1.5 MW/m2 |
Shown here pictures of a 5 m x 5 m x 3 m enclosure with double door entrance, for a robot mounted 2 kW fibre laser. This enclosure was supplied complete with interlock system, laser safe vents, CCTV and lighting.
CE Certified Laser Blocking Partitions
We also supply CE certified laser blocking partitions with or without doors, for dividing one laser lab into two or more sections. These semi-permanent partitions are cost effective and extremely quick to install, without the mess and fuss of building a brick or plasterboard wall. As such they offer an alternative to traditional methods of room division, and can also be easily undone at a later date if required. Alternatively they can be left as a permanent installation.
All partitions are tested and certified to EN 60825-4 with the following specification:
Irradiated Area |
PEL (T2) 100 s | PEL (T3) 10 s |
4 mm2 |
61 MW/m2 | 34 MW/m2 |
2000 mm2 |
2.7 MW/m2 | 1.5 MW/m2 |